TM 5-3895-369-14
(49)
(50)
(51)
Install sealing washer (47) bleeder valve
(46), and preformed packing (45) on screw
plug (44).
Install screw plug (44). Tighten screw plug
50 lb-ft (67.7 Nm). Tighten bleeder
valve (46) 121 to 174 lb-in. (14 - 20 Nm).
Install six shims (43) with flat side against
pump assembly.
Delivery valves separate into halves. If
delivery valves are dropped, damage will
result.
(52)
Immerse six pipe nipples (39) springs (41),
and delivery valves (42) in calibration fluid.
NOTE
Letters are engraved on distributor head
beside delivery valves. Refer to tags on
pipe nipples and match letters for proper
assembly.
(53)
Install six needle valves (42) springs (41)
shims (40), and pipe nipples (39). Tighten
pipe nipples alternately at 23 lb-ft (30 Nm).
(54)
Remove two screws (36) and install support
plate (38) with three screws (37 and 36).
Tighten screw (37) 23 lb-ft (30 Nm) and
screws (36) 86 to 258 lb-in. (10 - 29 Nm).
5-262