TM 5-3895-369-14
(39)
Measure governor shaft (55) clearance at
position C. Clearance limits are 0.059 to
0.0787 in. (1.5 - 2.0 mm). If measurement is
not within limits, adjust governor shaft and
measure clearance again. If measurement is
within limits, go to step (40).
(40) Install washer (54) and nut (53). Hold
governor shaft (55) securely and tighten nut
148 to 191 lb-in. (17 - 22 Nm).
(41)
Measure flyweight holder assembly clearance
at position D. Clearance limits are 0.0059 to
0.0138 in. (0.15 - 0.35 mm). If measurement
is not within limits, perform steps (42)
to (45). If measurement is within limits, go
to step (46).
5-259