TM 5-3895-369-14
(d)
Install dial gage in distributor
head (67).
(e)
Hold distributor head (67) horizontally
and lightly press plunger (70).
(f)
Measure plunger spring set length at
position A. If measurement is not
within limits, perform all following
steps. If measurement is within limits,
go to step (29).
(g)
Remove plunger assembly (70) up to
top spring seats (74) from distributor
head (67).
(h)
Install two shims (73) on spring
seats (74) and install plunger
assembly (70) on distributor head (67).
(i)
Repeat steps (26) (e) and (26) (f).
5-255