ADDITIVE SYSTEM PUMP REPAIR - Continued
ADDITIVE SYSTEM PUMP REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  1185    1186    1187    1188    1189  1190  1191    1192    1193    1194    1195  
img
TM 5-3895-369-14
(16) Install two packing glands (21) and clips (20)
with square head bolts (19) and
locknuts (18).
NOTE
Do not allow packing gland to become
cocked during assembly.
(17) Tighten two locknuts (18) evenly to ensure
proper seating of packing gland (21). After
seating packing gland, loosen locknuts l/2
turn.
(18) Install spring clip (17) in backplate (7).
(19) Install two pipe plugs (16) in case (8).
(20) Install key (15) in idler shaft (13).
(21) Install right-hand gear (14), idler shaft (13),
and left-hand gear (12) in case (8).
5-523