ADDITIVE SYSTEM PUMP REPAIR - Continued
ADDITIVE SYSTEM PUMP REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  1184    1185    1186    1187    1188  1189  1190    1191    1192    1193    1194  
img
TM 5-3895-369-14
5-88. ADDITIVE SYSTEM PUMP REPAIR (CONT).
(7) Install lock and seal nut (36) on adjusting screw (37) and install screw in plug and cap (38).
(8) Turn adjusting screw (37) until 1 5/8 in. (41.28 mm) gap exists between face of plug cap (38) and top of
adjusting screw. Tighten lock and seal nut (36).
(9) Install two dowel pins (35). gasket (34) and faceplate (33) on case (3) with 14 screws (32). Tighten screws
35 lb-ft (47 Nm).
(10) Install two keys (30 and 31) in drive shaft (25).
(11) Install sleeve bearings (28 and 29) in backplate (7).
(12) Install packing washer (27) and packing set (26) in backplate (7).
(13) Install drive shaft (25) and bearing (24) in backplate (7) with retaining ring (23).
(14) If removed, install two setscrews (22) in bearing assembly (24).
(15) Install bearing assembly (24) and retaining ring (23). Tighten two setscrews (22).
5-522