• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
HYDROSTATIC PUMP REPAIR - Continued
HYDROSTATIC PUMP REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  994    995    996    997    998  999  1000    1001    1002    1003    1004  
img
TM 5-3895-369-14
(2) Install two servo links (95) and servo
pistons (92) on swash plate (73) with four
pins (94) and eight retaining rings (93).
(3) If removed, install two servo springs (91)
with spring retainers (90), washers (89), and
screws (88).
(4) Positions swash plate (73) in pump (3).
(5) Install two bearings (76) on trunnions (72).
(6) Install two preformed packings (75),
shims (74), and trunnions (72) in pump (3)
with six lockwashers (71) and screws (70).
Tighten screws 27 to 37 lb-ft (36 - 50 Nm).
(7) Install four preformed packings (69) and two
servo housings (57) on pump (3).
(8) Install two locking retainers (68) with four
screws (67).
5-332