HYDROSTATIC PUMP REPAIR - Continued
HYDROSTATIC MOTOR REPLACEMENT

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  999    1000    1001    1002    1003  1004  1005    1006    1007    1008    1009  
img
.
TM 5-3895-369-14
NOTE
End cap is under slight spring pressure.
Install screws alternately in crisscross
pattern, few threads at a time until cap
seats evenly.
(35) Install valve plate (20) and pin (19).
(36) Install gasket (18), end cap (17) and lifting
bracket (16) on pump (3) with eight
washers (14 and 15) and screws (12 and 13).
(37) If removed, install pin (11).
(38) Install preformed packing (9) and six
springs (7) in housing (10).
(39) Install preformed packing (8) in sealing
ring (6) and scaling ring on housing (10).
(40) Install preformed packing (5) and bronze
seal (4).
(41) Install seal assembly (2) on shaft end of
pump (3) with retaining ring (1).
NOTE
Follow-on Maintenance: Install
hydrostatic pump (para 5-53).
END OF TASK