HYDROSTATIC PUMP REPAIR - Continued
HYDROSTATIC PUMP REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  990    991    992    993    994  995  996    997    998    999    1000  
img
TM 5-3895-369-14
(28) Position pump (3) on servo housings (57)
and remove 12 screws (58), washers (59),
lifting bracket (60), front cover (61), and
gasket (62).
(29) If damaged, remove pin (63) from front
cover (61).
(30) Remove shaft (64) from pump (3).
(31) Remove bearing (65) from shaft (64).
(32) Remove thrust plate (66).