HYDROSTATIC PUMP REPAIR - Continued
HYDROSTATIC PUMP REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  987    988    989    990    991  992  993    994    995    996    997  
img
TM 5-3895-369-14
NOTE
Before removing charge pump, matchmark
housing and main pump end cap.
(8) Remove four screws (21) and washers (22)
that form rectangular pattern on rear of
charge pump (23).
(9) Remove charge pump (23) and gasket (24)
from end cap (17). Discard gasket.
NOTE
Removal of charge check valves requires
drag link socket.
(10) Remove spacer (25) from base of charge
pump (23).
(11) Remove two screws (26) and washers (27).
(12) Remove end cap (28) and gasket (29).
Discard gasket.
(13) Remove two sleeves (30), middle
housing (31) and gasket (32) from base (23).
5-325