TM 5-3895-359-14&P
Install Thermostat
1. Affix a new gasket to each side of the thermostat
housing.
2. Set the new gasket and the thermostat in the
housing.
Attach the outlet elbow and the thermostat housing to
the water manifold.
Using a new seal connect the thermostat housing to the
water manifold.
3. Connect any other piping which may have been
disconnected.
4. Fill the cooling system and check for leaks.
Fig. 2 - Method of Checking Thermostat Operation
10-6-12