HYDROSTATIC PUMP REPLACEMENT - Continued
HYDROSTATIC PUMP REPLACEMENT - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  983    984    985    986    987  988  989    990    991    992    993  
img
TM 5-3895-369-14
Adhesive sealant can damage your eyes.
Wear safety goggles/glasses when using;
avoid contact with eyes. If sealant contacts
eyes, flush eyes with water and get
immediate medical attention.
Apply hydraulic thread sealant to
(3)
adaptor (22) and elbow (21) and install with
hose (20) to pump (4).
Apply hydraulic thread sealant to elbow (19)
(4)
and install with hose (18) on pump (4).
Secure hose (16) on port (17) with two brackets (15), four lockwashers (14), and screws (13).
(5)
Install hose (11) and tighten fitting (10) to
(6)
adaptor (12) on pump (4).
(7)
Secure hose (8) on port (9) with two
brackets (7), four lo&washers (6), and
screws (5).