HYDROSTATIC PUMP REPLACEMENT - Continued
HYDROSTATIC PUMP REPLACEMENT - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  982    983    984    985    986  987  988    989    990    991    992  
img
TM 5-3895-369-14
5-53. HYDROSTATIC PUMP REPLACEMENT (CONT).
Hydrostatic pump weighs 145 lbs (66 kg).
Attach suitable lifting device prior to
removal to prevent possible injury
to personnel.
(10)
Attach suitable lifting device to pump (4)
and remove four locknuts (23), washers (24),
and screws (25) from frame (26). Discard
locknuts.
(11)
While mechanic operates lifting device,
assistant guides the pump (4) from
frame (26).
b. Installation.
Hydrostatic pump weighs 145 lbs (66 kg).
Attach suitable lifting device prior to
removal to prevent possible injury
to personnel.
(1)
While mechanic operates lifting device, assistant guides the pump (4) onto frame (26).
(2)
Install pump (4) on frame (26) with four screws (25), washers (24), and locknuts (23). Remove lifting
device. Tighten locknuts 75 to 100 lb-ft (102 - 136 Nm).