• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
SHIFT FORK REPAIR
HYDROSTATIC PUMP REPLACEMENT

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  979    980    981    982    983  984  985    986    987    988    989  
img
.
TM 5-3895-369-14
b.
Cleaning/Inspection.
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use
only in well-ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors.
Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type I
drycleaning solvent is 100F (38C) and for type II is 140F (60C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help.
If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately flush
eyes with water and get immediate medical attention.
(1)
Clean all metal parts with drycleaning solvent.
(2)
Check all machined surfaces for damage.
(3)
Check all threads for peeled of crossed condition.
c.
Assembly.
(1)
Install shift fork (3) on shift fork shaft (4).
(2)
Align holes in fork (3) and shaft (4). Install square head bolt (2). Tighten bolt 25 to 30 lb-ft (34 - 41 Nm).
(3)
Install lockwire (1) through bolt (2).
NOTE
Follow-on Maintenance: Assemble/Install two-speed range box (para 5-50).
END OF TASK
5-317


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.