HELICAL AND SPUR GEAR ASSEMBLY REPAIR
SHIFT FORK REPAIR

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  977    978    979    980    981  982  983    984    985    986    987  
img
.
TM5-3895-369-14
b.
Cleaning/Inspection.
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use
only in well-ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors.
Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type I
drycleaning solvent is 100F (38C) and for type II is 140F (60C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help.
If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately flush
eyes with water and get immediate medical attention.
(1)
Clean all parts with drycleaning solvent.
(2)
Check all machined surfaces for damage.
(3)
Check bearings and bearing cups for damage.
( 4 ) Replace damaged parts.
Assembly.
c.
(1)
Install spacer (6), helical gear (5), and spacer (4) on shaft (2).
(2)
Install bearing (3) on shaft (2).
(3)
Install bearing (1) on spur gear end of
shaft (2).
NOTE
Follow-on Maintenance: Assemble two-speed range box (para 5-50).
END OF TASK