TM 5-3895-369-14
INJECTION PUMP MEASURING DEVICE
(7) Adjust idle injection quantity as follows:
(a) Install injection pump measuring device and fix lower control lever assembly (17) in minimum
speed position.
(b) Measure injection quantity. If quantity is not within limits, loosen nut (18) and adjust idle screw (19)
to get correct measurement. Tighten nut 52 to 78 lb-in. (6 - 9 Nm). If quantity is within limits,
perform following steps.
(c) Measure lower control lever assembly (17) angle at position A. If angle is not within limits, loosen
screw (20) and adjust middle control lever (21) to get correct angle. Tighten screw securely and
repeat step (a) to (b). If angle is within limits, go to step (9).
(d) If angle at position A cannot be adjusted within limits, remove injection pump measuring device,
flange nut (14), and intermediate disc (22).
(e) Position lower control lever assembly (17) to get correct angle and install intermediate disc (22) and
flange nut (14). Tighten flange nut 60 to 86 lb-in. (7 - 10 Nm).
Repeat steps (a) to (c).
(f)
5-269