FUEL INJECTION PUMP REPAIR - Continued
INJECTION PUMP MEASURING DEVICE

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  930    931    932    933    934  935  936    937    938    939    940  
img
TM 5-3895-369-14
NOTE
upper spring will come off with upper
control lever.
(5) Remove flange nut (14), upper spring (15),
and upper control lever (16).
(6) Install flange nut (14) on lower control lever
assembly (17). Tighten flange nut 60 to 86
lb-in (7 - 10 Nm).