FUEL INJECTION PUMP REPAIR - Continued
TURBOCHARGER REPAIR

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  936    937    938    939    940  941  942    943    944    945    946  
img
.
TM 5-3895-369-14
(20) Set up measuring cylinder and measure
overflow quantity from overflow valve at
specified pump speed with control lever (2)
in maximum position.
(21) Check to ensure that magnet valve operates
to end injection immediately at voltage,
pump speed, and control lever (2) position
specified in calibration data.
NOTE
Follow-on Maintenance: Install fuel injection pump (para 5-40).
END OF TASK