FUEL INJECTION PUMP REPAIR - Continued
FUEL INJECTION PUMP REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  920    921    922    923    924  925  926    927    928    929    930  
img
TM 5-3895-369-14
(36) Assemble flyweight holder assembly as
follows:
(a) Install cap (65) and plug (64).
(b) Immerse four flyweights (62),
washer (61). and sleeve (60) in
calibration fluid.
(c) Install four flyweights (62) washer (61).
and sleeve (60) in flyweight holder (63).
Ensure that square bottom of flyweight
holder assembly is aligned with shim or
injection pump will not function properly
and damage may result.
(37) Install shim (59) washer (58). and flyweight
holder assembly (57).
(38) Install preformed packing (56) on governor
shaft (55) and install governor shaft.