FUEL INJECTION PUMP REPAIR - Continued
FUEL INJECTION PUMP REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  917    918    919    920    921  922  923    924    925    926    927  
img
TM 5-3895-369-14
(d) Install dial gage in distributor
head (67).
(e) Hold distributor head (67) horizontally
and lightly press plunger (70).
Measure plunger spring set length at
(f)
position A. If measurement is not
within limits, perform all following
steps. If measurement is within limits,
go to step (29).
(g) Remove plunger assembly (70) up to
top spring seats (74) from distributor
head (67).
(h) Install two shims (73) on spring
seats (74) and install plunger
assembly (70) on distributor head (67).
Repeat steps (26) (e) and (26) (f).
(i)
5-255