HYDRAULIC GEAR PUMP ASSEMBLY REPLACEMENT - Continued
HYDRAULIC GEAR PUMP ASSEMBLY REPAIR

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  1143    1144    1145    1146    1147  1148  1149    1150    1151    1152    1153  
img
.
TM 5-3895-369-14
(6) Install preformed packing (11) and hose (10)
on pump (12) with two coupling halves (9),
four lo&washers (8) and screws (7).
Tighten screws 30 lb-ft (41 Nm).
Adhesive sealant causes immediate
bonding on contact with eyes, skin, or
clothing and also gives off harmful vapors.
Wear protective goggles and use in well-
ventilated area. If adhesive gets in eyes, try
to keep eyes open; flush eyes with water for
15 minutes and get immediate medical
attention.
(7) Coat threads of two elbow pipes (3 and 4)
with pipe thread scaling compound.
(8) Install two preformed packings (6 and 5) and
elbow pipes (4 and 3).
(9) Connect two hydraulic hoses (1 and 2).
NOTE
Follow-on maintenance: Close left engine door (para 2-14).
END OF TASK