STARTER ASSEMBLY TESTING
Table 5-3. Starter No-Load Test Specifications

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  954    955    956    957    958  959  960    961    962    963    964  
img
.
TM 5-3895-369-14
5-48. STARTER ASSEMBLY TESTING (CONT).
(3)
Perform following no-load test prior to disassembly:
(a)
Connect voltmeter from starter motor terminal to starter motor frame. Connect negative battery
cable to starter motor frame.
(b)
Mount tachometer to measure armature speed.
Ensure switch is open prior to connecting to starter solenoid. Electrical shock or physical injury may
result if starter is energized while making final battery connection.
Connect switch to solenoid battery terminal and solenoid switch terminal.
(c)
Connect ammeter in series between positive side of battery and battery terminal on starter solenoid.
(d)
Connect potentiometer between positive and negative battery terminals.
(e)
Close switch to operate starter and adjust potentiometer until voltmeter indicates 24 Vdc.
(f)
Record ammeter and tachometer readings.
(g)
Open switch to de-energize starter.
(h)
Refer to Table 5-3 for current and rpm performance specifications.
(i)
5-292