HORN REPLACEMENT
BACK-UP HORN ALARM SWITCH REPLACEMENT - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  420    421    422    423    424  425  426    427    428    429    430  
img
. . . .
TM 5-3895-369-14
4-85. BACK-UP HORN ALARM SWITCH REPLACEMENT.
This task covers:
a. Removal
b. Cleaning/Inspection
c. Installation
INlTlAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's: automotive
TM or Para
Condition Description
Para 4-97
Hydrostatic pump cover
MateriaIs/Parts
removed.
Cloth, lint-free (item 12, appendix E)
Para 4-90
Negative battery cables
Tag, identification (item 55, appendix E)
disconnected.
Lockwasher (2)
a.
Removal.
NOTE
Tag and mark all wires before removal.
(1) Remove two screws (1). Tag, mark and
remove wires (2 and 3) from switch (4).