TM 5-3895-369-14
4-81. FLOODLIGHT ASSEMBLY REPLACEMENT/REPAIR (CONT).
Installation.
e.
(1) Install spacer (10) and floodlight assembly
(9) in bracket (8) with lockwasher (7) and
nut (6).
(2) Connect connector (5).
(3) Install wire (2) and locknut (1) on screw (3).
Tighten locknut securely against floodlight
mount (4).
NOTE
Follow-on Maintenance: Connect negative battery cable (para 4-90).
END OF TASK