INSTRUMENT PANEL GAUGE REPLACEMENT - Continued
INSTRUMENT PANEL GAUGE REPLACEMENT - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  376    377    378    379    380  381  382    383    384    385    386  
img
TM 5-3895-369-14
(d) Remove gauge lamp (36) from water
temperature gauge (37).
(e) Remove two nuts (38),
lockwashers (39), and water
temperature gauge (37) from
instrument panel (9). Discard
lockwashers.
(4) To remove voltmeter, proceed as follows:
(a) Remove nut (40), lockwasher (41),
wire (12), and gauge lamp wire (42)
from terminal (43). Discard
lockwasher.
(b) Remove nut (44), lockwasher (45), and
wire (16) from terminal (46). Discard
lockwasher.