Section Ill. OPERATOR MAINTENANCE PROCEDURES
AIR FILTER INSPECTION AND SERVICE.

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  86    87    88    89    90  91  92    93    94    95    96  
img
. . .
TM 5-3895-369-14
3-6. ENGINE OIL LEVEL CHECK AND SERVICE (CONT).
b. Oil Level Service.
(1) Remove oil fill cap (4) from valve cover (5).
Do not overfill crankcase with engine oil
or serious damage will occur to engine.
(2) Add oil according to lubrication chart
(Figure 3-1).
(3) Install oil filler cap (4) on valve cover (5).
(4) Check crankcase oil level (para 3-6[a]).
3-7. ENGINE COOLANT CHECK AND SERVICE.
Use extreme care when removing the radiator pressure
cap. Sudden release of pressure can cause a steam flash
which could seriously injure personnel.
a.
Place clean, thick waste cloth over radiator
cap (1).
b. Slowly loosen cap (1) to first stop.
c.
Allow pressure to dissipate completely.
d. Remove cap (1).
e. If necessary, add coolant/antifreeze at 50/50
concentration of coolant/antifreeze to water.