Table 3-2. Operator Troubleshooting Procedures - CONT.
Table 3-2. Operator Troubleshooting Procedures - CONT.

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  82    83    84    85    86  87  88    89    90    91    92  
img
. . . . . . . .
TM 5-3895-369-14
Table 3-2. Operator Troubleshooting Procedures
CONT.
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM
INSTRUMENT PANEL LIGHTS DO NOT OPERATE.
1.
Step 1.
Ensure that ignition key switch turned ON.
If lights do not turn on, go to step 2.
Step 2.
Check instrument panel fuse (para 3-9).
If fuse is bad, replace fuse (para 3-9).
If fuse is good, notify unit maintenance.
GAUGES DO NOT OPERATE.
2.
Check instrument panel fuse (para 3-9).
If fuse is bad, replace fuse (para 3-9).
If fuse is good, notify unit maintenance.
FORWARD AND/OR REAR FLOODLIGHTS DO NOT OPERATE.
3.
Step 1.
Ensure light switch is turned ON.
If light switch is turned ON, go to step 2.
Step 2.
Check floodlight fuse (para 3-9).
If fuse is bad, replace (para 3-9).
If fuse is good, notify unit maintenance.
FUEL SYSTEM
ENGINE STARTS AND STOPS.
Step 1.
Check fuel level (para 3-10).
If fuel tank is empty, fill tank (para 3-10).
If there is fuel in tank, go to step 2.
3-16