PROPER USE OF MANOMETER
EXHAUST SMOKE ANALYSIS

Technical Manual For Mixer, Rotary Tiller, Soil Stabilization Diesel Engine Driven (Ded) Page Navigation
  482    483    484    485    486  487  488    489    490    491    492  
img
.
TM 5-3895-359-14&P
PRESSURE CONVERSION CHART
diameter of the tube or to the pressure imposed, the
accuracy of the reading obtained is not impaired.
1" water
=
.0735" mercury
1' water
=
.0361 psi
Refer to Table 3 to convert the manometer reading into
1" mercury
=
13.6000" water
other units of measurement.
1" mercury
=
.4910 psi
1 psi
=
27.7000" water
1 psi
=
2.0360" mercury
1 psi
=
6.895 kPa
1 kPa
=
.145 psi
TABLE 3