EXHAUST SMOKE ANALYSIS
HARD STARTING

Technical Manual For Mixer, Rotary Tiller, Soil Stabilization Diesel Engine Driven (Ded) Page Navigation
  484    485    486    487    488  489  490    491    492    493    494  
img
. .
TM 5-3895-359-14&P
Chart 1
EXHAUST SMOKE ANALYSIS
SUGGESTED REMEDY
injectors and perform the appropriate governor tune-up.
1. High exhaust back pressure or a restricted air inlet
causes insufficient air for combustion and will result in
Replace faulty injectors if this condition still persists
incompletely burned fuel.
after timing the injectors and performing the engine
tune-up.
Avoid lugging the engine as this will cause incomplete
High exhaust back pressure is caused by faulty exhaust
combustion.
piping or muffler obstruction and is measured at the
exhaust manifold outlet with a manometer.  Replace
2. Check for use of an improper grade of fuel. Refer to
faulty parts.
Fuel Oil Specifications on Page 10-9-7.
3. Check for internal lubricating oil leaks and refer to
Restricted air inlet to the engine cylinders is caused by
the High Lubricating Oil Consumption chart.
clogged cylinder liner ports, air cleaner or blower air
inlet screen. Clean these items. Check the emergency
4. Check for faulty injectors and replace as necessary.
stop to make sure that it is completely open and readjust
it if necessary.
Check for low compression and consult the Hard
Starting chart.
The use of low cetane fuel will cause this condition.
Check for improperly timed injectors and improperly
Refer to Fuel Oil Specifications on Page 10-9-7.
positioned injector rack control levers.  Time the fuel
10-11-15