Fig. 2 - Variable Speed Governor Mounting
Fig. 7. Removing Operating Shaft from Operating Fork

Technical Manual For Mixer, Rotary Tiller, Soil Stabilization Diesel Engine Driven (Ded) Page Navigation
  323    324    325    326    327  328  329    330    331    332    333  
img
. . .
TM 5-3895-359-14&P
Fig. 4 - Removing Bearings from Cover using Tool
J 21967-01
discarded on removal as it becomes
brinnelled
during
the
disassembly
process.
Fig. 5 Governor Control Housing Details and
f. Use tool J 4880 and remove one lock ring
Relative Location of Parts
from each weight pin. Withdraw the pins,
flat washers and governor weights.
c. Remove the plain washer and seal from
g. If required, the weight carrier may be
the shaft.
pressed from the governor weight shaft
d. Remove one screw and lock washer and
and a new carrier installed (Fig. 9).
remove the spring housing cover and
gasket. Then remove the set screw from
4. Disassemble the governor variable speed spring
the spring lever.
housing.
e. Support the spring housing on the bed of
the press with the shaft up. Use a brass
a. Refer to Fig. I and withdraw the variable
rod and press the shaft, plug and bearing
speed spring, stops, spring plunger and
from the housing.  Remove the bearing
shims from the spring housing.
from the shaft and the spring lever from
b. Loosen the bolt and withdraw the speed
the housing.
control lever from the speed control lever
shaft (Fig. 1). Remove the Woodruff key
from the shaft (Fig. 13).
10-3-42