VARIABLE DISPLACEMENT PUMP - Continued
VARIABLE DISPLACEMENT PUMP - Continued

Technical Manual For Mixer, Rotary Tiller, Soil Stabilization Diesel Engine Driven (Ded) Page Navigation
  112    113    114    115    116  117  118    119    120    121    122  
img
TM 5-3895-359-14&P
When installing the swashplate assembly into the
housing, the feedback link must be laid back along the
top of the swashplate so it can be reached through the
opening for the control valve.
After installing swashplate be certain feedback link is
accessible.
Install the trunnions, checking for proper orientation with
the housing and tighten the cap screws. The swashplate
should have no side play yet rotate freely. If necessary,
alter the plastic shims to obtain the proper adjustment.
Install and tighten the trunnion cap screws.
6-41