VARIABLE DISPLACEMENT PUMP - Continued
VARIABLE DISPLACEMENT PUMP - Continued

Technical Manual For Mixer, Rotary Tiller, Soil Stabilization Diesel Engine Driven (Ded) Page Navigation
  109    110    111    112    113  114  115    116    117    118    119  
img
TM 5-3895-359-14&P
After removing the retainers, scribe a line to mark the
height of the servo housing in relation to the pump
housing.
Unscrew the servo housings using channellock pliers to
grip the flats on top of the housings.
At this time the servo springs should be removed of
replacement is necessary as the pump housing will
provide a means of leverage when breaking the
breaking the screws loose.
6-38