TM 5-3895-372-10
(a) Concrete-Mobilemixer serial number
(c) Cement discharge turns - (K)
(d) Concrete strength - (C)
(e) Cement meter count (cu yd) - (T)
(f) Lbs/cu yd - (F)
(g) Sand dial setting - (3)
(h) Lbs/cu yd - (D)
(i) Stone dial setting - (4)
(j) Lbs/cu yd - (E)
(k) Water gal/cu yd - (H)
(I) Water setting dry sand - (S)
(m) Water setting normal sand - (W)
(o) Amount per quart - (note)
(p) Flowmeter setting - (4)
(r) Flowmeter setting - (4)
k. Meter-Feeder Calibration.
NOTE
The mixer cannot produce good concrete if meter calibration is inaccurate. If there is any doubt
the accuracy of cement delivery, check calibration. This procedure should be done by the
operator with organizational supervision. Be sure to perform all Preparation steps (Item 1) before
starting Calibration (Item 2). Check calibration at least once a year.
2-16