TM 5-3895-369-14
FAN HUB INSPECTION
(b) If fan hub is OK indicates faulty
drive line components.
(1) Remove drive belt (para 466).
(2) Measure fan end-play at position A.
(a) If measurement is greater than
0.006 inch (0.15 mm), replace fan
support
WATER PUMP INSPECTION
(1) Disconnect negative battery cable
(para 4-90).
(2) Remove drive belt (para 4-66).
(3) Check water pump for free rotation.
(a) If water pump does not turn
freely or rattles, replace (4-65).
(b) If water pump is OK, indicates
faulty air inlet pipe.
4 - 1 0 5