GATE CYLINDER REPAIR - Continued
ADDITIVE SYSTEM PUMP REPAIR

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  1177    1178    1179    1180    1181  1182  1183    1184    1185    1186    1187  
img
.
TM 5-3895-369-14
(3) Install rod guide (11) on piston rod (5).
(4) Install crown seal (10) and wear ring (9) on
piston (7).
(5) Install preformed packing (8) on piston
rod (5).
(6) Install piston (7) on piston rod (5) with
locknut (6).
(7) Lubricate piston rod (5), assembled parts,
and inside of cylinder body (2) with
hydraulic fluid.
(8) Install piston rod (5) and assembled parts in
cylinder body (2) with two retaining
rings (3 and 4).
Sealant can damage your eyes. Wear safety
goggles/glasses when using; avoid contact
with eyes. If sealant contacts eyes, flush
eyes with water and get immediate medical
attention.
(9) Apply hydraulic sealant to threads of two
fittings (1) and install fittings in cylinder
body (2).
NOTE
Follow-on Maintenance: Install gate cylinder (para 4-146).
END OF TASK