ADDITIVE SYSTEM MOTOR REPLACEMENT/REPAIR - Continued
ADDITIVE SYSTEM MOTOR REPLACEMENT/REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  1136    1137    1138    1139    1140  1141  1142    1143    1144    1145    1146  
img
TM 6-3895-369-14
5-80. ADDITIVE SYSTEM MOTOR REPLACEMENT/REPAIR (CONT).
(10) If removed, install roller bearing (13) in
backing plate (8).
(11) Position cam plate (11) in housing (9).
(12) Align matchmarks and install preformed
packing (12) and backing plate (8) with six
screws (10). Tighten screws alternately
32 lb-ft (43 N-m).
Adhesive sealant causes immediate
bonding on contact with eyes, skin, or
clothing and also gives off harmful vapors.
Wear protective goggles and use in well-
ventilated area. If adhesive gets in eyes, try
to keep eyes open; flush eyes with water for
15 minutes and get immediate medical
attention.
(13) Coat threads of three elbows (3,4, and 5)
with hydraulic sealant.
(14) Install three preformed packings (6 and 7)
and elbows (3,4, and 5).
(15) Install key (1) in shaft (2).
5-474