EMERGENCY STEERING UNIT REPAIR - Continued
EMERGENCY STEERING UNIT REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  1116    1117    1118    1119    1120  1121  1122    1123    1124    1125    1126  
img
TM 5-3895-369-14
5-77. EMERGENCY STEERING UNIT REPAIR (CONT).
(12) Remove two screws (33), lockwashers (34),
and motor (32) from motor base (23).
Discard lo&washers.
b. Cleaning/lnspection.
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use
only in well-ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors.
Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type I
drycleaning solvent is 100F (38C) and for type II is 140F (60C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help.
If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately flush
eyes with water and get immediate medical attention.
Compressed air used for cleaning purposes must not exceed 30 psi (207 kPa). Use only with effective
chip guarding and personal protective equipment (goggles/shields, gloves, etc.).
(1) Clean all metal parts with drycleaning solvent and dry with lint-free cloth or compressed air.
(2) Check housing and components for cracks and wear.
(3) Check threads for crossed or peeled condition.
(4) Replace damaged parts.
5-454