• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
EMERGENCY STEERING UNIT REPAIR - Continued
STEERING CYLINDER REPAIR

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  1118    1119    1120    1121    1122  1123  1124    1125    1126    1127    1128  
img
.
TM 5-3895-369-14
5-77. EMERGENCY STEERING UNIT REPAIR (CONT).
Adhesive sealant causes immediate
bonding on contact with eyes, skin, or
clothing and also gives off harmful vapors.
Wear protective goggles and use in well-
ventilated area. If adhesive gets in eyes, try
to keep eyes open; flush eyes with water for
15 minutes and get immediate medical
attention.
(4) Apply hydraulic sealant to threads of three
fittings (24,18, and 17) and three
adaptors (25,20, and 19).
(5) Install preformed packing (26), adaptor (25) and fitting (24) on motor base (23).
(6) Install two preformed packings (21 and 22), adaptors (19 and 20), and fittings (17 and 18) on motor
base (23).
(7) Install hose (16) to fittings (17 and 18)
(8) Install solenoid (12) and tighten clamp (15)
securely.
NOTE
Refer to tags to properly install wires.
(9) Install grey solenoid lead (4) on
solenoid (12) with lockwasher (14), and
nut (13).
(10) Install black solenoid lead (8) on
solenoid (12) with lockwasher (11) and
nut (10).
(11) Install solenoid lead (8) on terminal (9) with
lockwasher (7) and nut (6).
(12) Install grey solenoid lead (4) and ground
lead (3) on terminal (5) with lockwasher (2)
and nut (1).
NOTE
Follow-on Maintenance: Install
emergency steering unit (para 4-119).
END OF TASK
5-456


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.