TM 5-3895-369-14
(4) Install grease fitting (8) and position four
seals (3) on universal joint (4).
(5) Position universal joint (4), quick disconnect
yoke (6) and male yoke (2).
Be careful when removing bearing cups, or
needle bearings may fall out and be
damaged or lost.
(6) Apply grease to insides of four bearing
cups (7) and install cups in male yoke (2)
and quick disconnect yoke (6) over ends of
universal joint (4).
(7) Install four retaining rings (5) and slide grease seals (3) into place.
(8) Repeat steps (1) through (7) for female yoke.
(9) Align matchmarks and install male yoke (2)
in female yoke (1).
NOTE
Follow-on Maintenance:
Install PTO drive shaft (para 4-101).
Lubricate PTO shaft (figure 3-1).
END OF TASK