PUMP DRIVE SHAFT REPAIR
PUMP DRIVE SHAFT REPAIR - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  1020    1021    1022    1023    1024  1025  1026    1027    1028    1029    1030  
img
TM 5-3895-369-14
(3) Place slip yoke (4) in vise and slide four
grease seals (7) down onto universal
joint (8).
(4) Remove four clips (9) from flange yoke (10)
and slip yoke (4). Discard clips.
Be careful when removing bearing caps.
Needle bearings may fall out and be
damaged or lost.
(5) Remove four bearing caps (11) from flange
yoke (10) and slip yoke (4).
(6) Remove flange yoke (10) and universal joint (8).
(7) Remove four grease seals (7) and grease fitting (12) from universal joint (8). Discard seals.
(8) Remove grease fitting (13) from slip shaft (4).
(9) Place drive shaft (3) in vise and slide four
grease seals (14) down onto universal
joint (15).
(10) Remove two clips (16) from drive shaft
yoke (17). Discard clips.
(11) Remove four bearing caps (18) from drive
shaft yoke (17) and universal joint (15).
Be careful when removing bearing caps.
Needle bearings may fall out and be
damaged or lost.
(12) Remove universal joint (15), four grease seals (14), and grease fitting (19). Discard seals.