4-98. HYDROSTATIC PUMP CABLE REPLACEMENT (CONT).
(2) Loosen two nuts (5 and 6) and remove
cable (7) from bracket (8).
(3) Remove clevis (3), jamnut (9), nut (5),
washer (10), nut (6), and nut (11) from
cable (7).
b. Installation.
(1) Install nut (11), nut (6), washer (10), nut (5),
jamnut (9), and clevis (3) on cable (7).
(2) Install cable (7) in bracket (8).
(3) Tighten two nuts (5 and 6) against
bracket (8).