HYDROSTATIC PUMP CABLE REPLACEMENT - Continued
PUMP DRIVE SHAFT REPLACEMENT

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  453    454    455    456    457  458  459    460    461    462    463  
img
. . .
TM 5-3895-369-14
4-99. HYDROSTATIC PUMP CABLE ADJUSTMENT.
This task covers:
Adjustment
INITIAL SETUP
Equipment Condition
Tools
TM or Para
Condition Description
Tool kit, general mechanic's: equipment
Para 2-2
maintenance and repair
Pump control lever in
neutral position.
Para 4-97
Hydrostatic pump cover
removed.
Chock wheels.
Adjustment.
(1) Loosen two nuts (1 and 2) and remove
cable (3) from bracket (4).
(2) Turn clevis (5) until it holds pump lever (6)
in detent position.
(3) Install cable (3) on bracket (4) and tighten
two nuts (2 and 1).
NOTE
Follow-on Maintenance: Install hydrostatic pump cover (para 4-97).
END OF TASK