TACHOMETER REPLACEMENT - Continued
TACHOMETER REPLACEMENT - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  385    386    387    388    389  390  391    392    393    394    395  
img
TM 5-3895-369-14
4-75. TACHOMETER REPLACEMENT (CONT).
(7) Remove two nuts (20), lockwashers (21),
bracket (22), and tachometer (4) from
instrument panel (23).
(8) Remove gauge lamp (24) from
tachometer (4).
b. Cleaning/Inspection.
(1) Clean any remaining sealant from
tachometer and instrument panel.
(2) Inspect wiring for excessive heat indicated by
brown or blackening of wire insulation.
Replace as necessary.
(3) Inspect for broken, striped or cracked
insulation allowing wiring to show through.
Replace as necessary.
c. Installation.
(1) Install gauge lamp (24) in tachometer (4).
Adhesive causes immediate bonding on
contact with eyes, skin, or clothing and also
gives off harmful vapors. Wear protective
goggles and use in well-ventilated area. If
adhesive gets in eyes, try to keep eyes open;
flush eyes with water for 15 minutes and
get immediate medical attention.
(2) Apply silicone sealant around tachometer
(4) and install in instrument panel (23) with
bracket (22), two lockwashers (21), and
nuts (20).