4-48. FUEL SHUTOFF VALVE AND SCREEN REPLACEMENT.
This task covers:
b. Installation
a. Removal
INITIAL SETUP
Equipment Condition
Tools
Condition Description
TM or Para
Tool kit, general mechanic's: automotive
Fuel/hydraulic tank
Para 4-49
removed.
Materials/Parts
Fuel shutoff valve closed.
Para 2-17
Sealant, hydraulic (item 52, appendix E)
Special Environmental Conditions
Work in well ventilated area.
Fuel vapors are flammable.
Do not smoke within 50 ft. (15 m).
Removal.
a.
(1) Remove fuel valve assembly (1) from
tank (2).
(2) Remove fuel valve screen (3) from fuel valve
assembly (1).
Installation.
b.
(1) Install fuel valve screen (3) to fuel valve
assembly (1).
(2) Apply thread locking sealant to threads of
valve assembly (1) and install in tank (2).
NOTE
Follow-on Maintenance: Install
fuel/hydraulic tank (para 4-49).
END OF TASK