ENGINE FAILS TO CRANK OR CRANKS SLOWLY WITH CLUTCH DISENGAGED. - Continued
ENGINE FAILS TO CRANK OR CRANKS SLOWLY WITH CLUTCH DISENGAGED. - Continued

Maintenance Manual For Mixer, Rotary Tiller Page Navigation
  108    109    110    111    112  113  114    115    116    117    118  
img
. . .
TM 5-3895-369-l4
Remove all jewelry such as rings, dog tags, bracelets, etc. lf jewelry contacts battery terminal, a direct
short may result in instant heating of tools, damage to equipment, and injury or death to personnel.
BATTERY CABLE INSPECTION
(1) Open right engine door (para 2-14).
(2) Check for loose, dirty, or damaged
connections and battery cables (pare
4-90).
(a) if cables and/or connections
are faulty, batteries will not
maintain proper voltage.
(b) if cables and/or connections
are ok, indicates faulty starter
motor cables and/or
connections.
STARTER MOTOR CABLE
INSPECTION
(1) Open right engine door (pare 2-14).
(2) Check for loose, dirty, or damaged
connections and starter cables
(para 4-71).
(a) if cables and/or connections
are faulty, repair/replace
(pare 4-72).
(b) lf cables and/or connections
are ok, indicates faulty solenoid
ignition switch.
4-17