TM 5-3895-359-14&P
After removing the retainers, scribe a line to mark the
height of the servo housing in relation to the pump
housing.
Unscrew the servo housings using channellock pliers to
grip the flats on top of the housings.
At this time the servo springs should be removed of
replacement is necessary as the pump housing will
provide a means of leverage when breaking the
breaking the screws loose.
6-38