TM 5-3895-369-14
(2)
Remove two nuts (7), lockwashers (8),
screws (9), and flow control valve (6) from
mount (10). Discard lo&washers.
b. Installation.
(1)
Install flow control valve (6) on mount (10)
with two screws (9), lockwashers (8), and
nuts (7).
(2)
Install four hoses (4, 3, 2, and 1) and wire (5)
on flow control valve (6).
NOTE
Follow-on Maintenance:
Install forward floor plate (para 4-132).
Open hydraulic tank shut-off valves (para 2-11).
Fill hydraulic tank to proper level (para 3-11).
END OF TASK