TM 5-3895-369-14
4-92. BATTERY TESTING.
Reference TM 9-6140-200-14, Operators Organizational, Direct Support, and General Support Maintenance Manual
for Lead Acid Storage Batteries.
4-93. GROUND WIRE REPLACEMENT.
This task covers:
a. Removal
b. Cleaning/Inspection
c. Installation
INITIAL SETUP
Tools
Tool kit, general mechanics: automotive
Materials/Parts
Lockwasher
Locknut
Equipment Condition
TM or Para
Para 4-132
Para 4-90
Condition Description
Forward floor plate
removed.
Negative battery cable
disconnected.
a.
Removal.
(1)
Remove locknut (1), screw (2) and ground wire (3) from firewall mount (4). Discard locknut.
(2)
Remove screw (5), lockwasher (6), and ground cable (3) from clutch housing (7). Discard lockwasher.
4-346