TM 6-3895-369-14
5-80. ADDITIVE SYSTEM MOTOR REPLACEMENT/REPAIR (CONT).
(10)
(11)
(12)
If removed, install roller bearing (13) in
backing plate (8).
Position cam plate (11) in housing (9).
Align matchmarks and install preformed
packing (12) and backing plate (8) with six
screws (10). Tighten screws alternately
32 lb-ft (43 N-m).
Adhesive sealant causes immediate
bonding on contact with eyes, skin, or
clothing and also gives off harmful vapors.
Wear protective goggles and use in well-
ventilated area. If adhesive gets in eyes, try
to keep eyes open; flush eyes with water for
15 minutes and get immediate medical
attention.
(13)
Coat threads of three elbows (3,4, and 5)
with hydraulic sealant.
(14)
Install three preformed packings (6 and 7)
and elbows (3,4, and 5).
(15)
Install key (1) in shaft (2).
5-474