TM 5-3895-369-14
(2)
Place male yoke (2) in vise and slide four
grease seals (3) down onto universal
joint (4). Discard grease seals.
(3)
Remove four retaining rings (5) from quick
disconnect yoke (6) and male yoke (2).
Be careful when removing bearing cups, or
needle bearings may fall out and be
damaged or lost.
(4)
(5)
(6)
(7)
(8)
(9)
(10)
Remove four bearing cups (7) from quick
disconnect yoke (6) and male yoke (2).
Remove quick disconnect yoke (6) and universal joint (4) from male yoke (2).
Remove seals (3) and grease fitting (8) from universal joint (4).
Repeat steps (2) through (6) for female yoke.
Remove two locknuts (9) and screws (10).
Discard locknuts.
Remove retaining ring (11) and shaft (12)
from male yoke (2).
Remove grease fitting (13).
5-365