TM 5-3895-369-14
(5)
Remove two screws (17), lockwashers (18), and washers (19) from motor (6). Discard lockwashers.
Hydrostatic motor weighs 90 lbs (41 kg). Use care when removing or injury to personnel may result.
(6)
Mechanic and assistant remove motor (6) and gasket (20) from two-speed range box (21). Discard gasket.
(7)
Remove elbow (13) and adaptor (22) from
motor (6).
b. Installation.
Adhesive sealant can damage your eyes.
Wear safety goggles/glasses when using;
avoid contact with eyes. If sealant contacts
eyes, flush eyes with water and get
immediate medical attention.
(1)
Apply hydraulic sealant to threads of
adaptor (22) and elbow (13) and install on
motor (6).
5-341